Electrosurgical Unit || ESU-X 400 HT
99 Memory Programs
Stored Programs can be Selected Simply by the push of one button. Preset Programs are available for Cardio Surgery, Neuro Surgery, General and Laparoscopic Surgery, Flexible Endoscopy or Rigid Monopolar Endoscopy Under Liquid (TUR) and for Bipolar only use. The unit always remembers the last settings it was switched off with
10 Monopolar Currents
Perfectly suitable for all Surgical needs including TUR (Monopolar resection under liquid) and Vaporisation, Also available is a special A. ENDO mode for blend cut with alternate phases of pure cut and coagulation in flexible endoscopy and A Pure and A. Blend modes combined with a constant voltage system, that automatically adjusts the powers by keeping the electric are Constant. This provides for very delicate way of cutting and minimal superficial necrosis.
Neutral Electrode Alarm
When the contact surface of a dual split-type neutral electrode plate decreases to 50%, output powers will be limited to max. 400W. The power will be totally cut off and alarm will be activated in case contact decreases further to an insufficient level or in case that the cable gets disconnected or broken, for maximum safety.
HF Leakage Monitoring
Automatically reducing the output powers in order to meet, even in critical situations (i.e contact between patient and metalic parts of OT-table). safe values reducing potential risks involved (i.e burns).
Active Monopolar Outputs
For push-button handswitches with USA 3-pin connectors or Monopolar electrode cable and handles Activation even simultaneously possible by two surgeons by using hand switch or twin foot pedal. A special universal adapter is optionally available for connection multiple accessories with 2 to 8mm plugs.
7 Bipolar Currents
For all Surgical needs and with special Precise mode for Micro Precise Bipolar Coagulation and the Sealing mode for Bipolar Coagulation and Confidently ligating and sealing large vessels. Auto mode with Automatic Start / Stop system and impendance sensing for manual operation activates the HF current Automatically once the tissue is being touched.
Total Safety Concept
With complete self-test, hardware/software diagnosis and total function and safety monitoring by to 32 bit microprocessors. Dynamic auto-adjustment of output powers for best performance while using the lowest possible powers and reducing damaging side effects on target points (i.e carbonization or tissue sticking).
2 Bipolar Output
For cable 2 x 4mm USA-type banana plug connectors for Bipolar cut and coagulation with maximum safety and precision.
Powerfull Performance
Output power 400W max in monopolar pure cut and 160W max. in Bipolar cut. Constant output power levels through the output power control system make this unit particularly suitable for cutting under water (e.g during TUR). Power can be progressively adjusted to the desired level under visual control.